BD Microlance Hypodermic Needle 18 30G
Becton Dickinson
Medical device - hypodermic needleSingle-use 18G 40 mm conventional needle
Certifications
- CE marked (CE 0318) compliant with EU Medical Devices Directive / Regulation.
- Manufactured under ISO 13485 / ISO 9001 certified quality management system.
- Meets standards EN ISO 7864 (Sterile hypodermic needles for single use), EN ISO 6009 (colour Coding for identification), EN ISO 9626 (stainless steel tubing) and ISO 594 1/594 2 for luer fittings.
- Latex Free, non Pyrogenic design, and free from DEHP and phthalates per REACH compliance documentation.
- CE marked (CE 0318) compliant with EU Medical Devices Directive / Regulation.
- Manufactured under ISO 13485 / ISO 9001 certified quality management system.
- Meets standards EN ISO 7864 (Sterile hypodermic needles for single use), EN ISO 6009 (colour Coding for identification), EN ISO 9626 (stainless steel tubing) and ISO 594 1/594 2 for luer fittings.
- Latex Free, non Pyrogenic design, and free from DEHP and phthalates per REACH compliance documentation.
Single-use 18G 40 mm conventional needle
Description
A sterile, single-use 18G × 40 mm (1.5 inch) hypodermic needle from BD’s Microlance™ 3 conventional needle range. The pink-hub needle is designed for injection or aspiration of medical fluids — including medications, fluids or blood — and is compatible with standard Luer-lock or Luer-slip syringes. It offers a precise 3-cut bevel stainless steel cannula with medical-grade silicone lubrication for smooth penetration and minimal tissue trauma.
Bnefits
- Precise 3-angle bevel design for smooth and sharp penetration and reduced tissue trauma.
- Thin-wall stainless steel cannula ensures reliable flow rates for injections or aspirations.
- Sterile, single-use and latex-free — reducing risk of infection and allergic reactions.
- Compatible with standard Luer-lock or Luer-slip syringes for broad clinical applicability.
- Colour-coded pink hub (18G) enables quick identification and organisation in clinical/ag- aesthetic settings.
- Manufactured under ISO / CE-certified standards, ensuring compliance with medical device regulations.
Indications
- Intramuscular, intravenous, subcutaneous injection of medications or fluids.
- Aspiration or withdrawal of bodily fluids (e.g. blood sampling), where 18G × 40 mm needle is clinically appropriate.
- Aesthetic procedures requiring reliable needle insertion for filler, mesotherapy or other injectable preparations — when 18G gauge and 40 mm length is required.
- General clinical or surgical settings needing conventional hypodermic needles for injection or fluid aspiration.
Composition
- Cannula: stainless steel AISI 304 (chromium-nickel-manganese-silicon alloy)
- Needle hub and shield: colour-coded polypropylene (pink)
- Bonding agent: epoxy resin used to attach needle to hub
- Lubricant: medical-grade silicone oil applied to cannula (< 0.25 mg/cm²) to reduce insertion friction.
Formulation
- Sterile, single-use conventional hypodermic needle, 18G × 40 mm, regular bevel, thin-wall cannula, colour-coded pink hub, compatible with Luer-slip or Luer-lock syringes.
Packaging
- Individually sterile-wrapped needles (single-pack) per BD packaging standards.
- Shelf box containing 100 needles.
- Bulk/shipping case holds 5000 or more units (depending on distributor), per BD logistics documentation.
- Packaging includes CE mark (CE 0318) and manufacturing site identifier (Fraga, Spain).
Usage
- Select appropriate syringe (Luer-lock or Luer-slip) and ensure compatibility.
- Ensure needle packaging is intact; do not use if opened or compromised.
- Attach the needle securely to the syringe using Luer connection.
- Perform injection or aspiration per clinical or aesthetic protocol, following aseptic technique.
- Use only once; do not reuse to prevent cross-contamination or infection.
- Dispose of used needle immediately into a proper sharps container as per local regulations.
Contraindications
- Do not use if sterile packaging is damaged or opened.
- Not for reuse — single-use only; reuse increases risk of infection and needle degradation.
- Not suitable for patients with known allergy to stainless steel or silicone lubricant (rare).
- Do not use for applications requiring non-hypodermic needle types (e.g. blood collection requiring butterfly needles) unless clinically indicated.
Adverse Effects
- Local pain, bruising, bleeding, erythema or swelling at injection/aspiration site.
- Risk of infection or abscess if aseptic technique is not followed.
- Needle breakage or bending if misused or subjected to lateral force before/during insertion.
- Potential discomfort due to needle size (18G is relatively large diameter compared with finer gauges).
Storage Conditions
- Store in original sealed packaging until use to maintain sterility.
- Store in a cool, dry environment away from direct sunlight, extreme heat or moisture.
- Protect from physical damage or deformation (especially needle bending).
- Keep out of reach of children and unauthorised persons; dispose of appropriately after use.
Duration
Onset
Browse more Medical device - hypodermic needle
Bd Microfine+ Range
Multiple distributors
Bd Microfine+ Range
Medical and Aesthetic Equipment
- £22.00
- £22
- 40 more
BD Venflon Cannula and Catheter Range
Multiple distributors
BD Venflon Cannula and Catheter Range
Clinic Essentials
- £83.99
- £15.99
- 23 more
BD Emerald™ Syringe Range
Multiple distributors
BD Emerald™ Syringe Range
Medical and Aesthetic Equipment
- £9.99
- £8.99
- 17 more
BD Eclipse Hypodermic Needle Range
Medisave
BD Eclipse Hypodermic Needle Range
Medical and Aesthetic Equipment
- £21.59
- £23.99
- 13 more
BD Luer Syringe Range
Multiple distributors
BD Luer Syringe Range
Medical and Aesthetic Equipment
- £31.19
- £51.59
- 10 more
BD Microtainer™ Tubes with Microgard™ Closure K2EDTA 250–500µL
Medisave
BD Microtainer™ Tubes with Microgard™ Closure K2EDTA 250–500µL
Clinic Essentials
- £69.59
- £58.79
- 6 more
BD Vacutainer® Push Button Blood Collection Set, 25G x 0.75\ with 7\ Tubing and Luer Adapter – Box of 50
Medisave
BD Vacutainer® Push Button Blood Collection Set, 25G x 0.75\ with 7\ Tubing and Luer Adapter – Box of 50
Medical and Aesthetic Equipment
- £89.99
- £89.99
- 5 more
BD Whitacre Pencil Point Spinal Needle 22-27G
Medisave
BD Whitacre Pencil Point Spinal Needle 22-27G
Medical and Aesthetic Equipment
- £317.99
- £323.99
- 4 more
Venflon I.V Cannula 18-22G (50)
Teleta
Venflon I.V Cannula 18-22G (50)
Clinic Essentials
- £1.50
- £64.99
- 4 more
BD™ Blunt Fill Needle 18 G x 1 in. special packaging
Multiple distributors
BD™ Blunt Fill Needle 18 G x 1 in. special packaging
Medical and Aesthetic Equipment
- £15.99
- £275.99
- 4 more
BD Micro-Fine™ Plus U-100 1 mL Insulin Syringe with 29-30G x 12.7 mm Needle
Multiple distributors
BD Micro-Fine™ Plus U-100 1 mL Insulin Syringe with 29-30G x 12.7 mm Needle
Medical and Aesthetic Equipment
- £21.60
- £2.50
- 4 more
BD Quincke Spinal Needle - 22G x 2.5\ (0.7 mm x 63 mm) - Black Hub - Box of 25
Medisave
BD Quincke Spinal Needle - 22G x 2.5\ (0.7 mm x 63 mm) - Black Hub - Box of 25
Medical and Aesthetic Equipment
- £83.99
- £81.59
- 3 more













